LSC-110 Slide Stainer

Description

Frozen section specimens: Step 1: Fix specimen cylinder number 1 (20 seconds) → Step 2
Washing cylinder number 4 (10 seconds) → Step 3 HE staining jar number 2 (1 minute 20 seconds)
→ Step 4: Wash the tank number 4 (10 seconds) → Step 5: Differentiate the tank number 3 (1 time)
→ Step 6: Wash the tank number 4 (10 seconds) → Step 7: Unblue tank number 7 (10 seconds) →
Step 8, washing tank number 4 (10 seconds) → Step 9, Ehong tank number 8 (3 seconds) → Step
10, washing tank number 4 (3 seconds) → Step 11: 75% alcohol tank number 9 (6 seconds) → Step
12: Water washing tank number 4 (set 0) → Step 13: 85% alcohol tank number 10 (6 seconds) →
Step 14: 95 % alcohol cylinder number 11 (6 seconds) → Step 15 100% alcohol cylinder number 12
(6 seconds) → Step 16 100% alcohol cylinder number 13 (6 seconds) → Step 17 xylene cylinder
Position number 14 (6 seconds) → Step 18 Xylene cylinder position number 15 (end in 1 second)

Main Technical Data:
1. Number of liquid cylinders: 15:
2. The first cylinder is an automatic start-up saving cylinder.
3. Number of cleaning tanks: 3
4. Number of hematoxylin tanks: 1 (water bath heating)
5. Number of differentiation tanks: 1
6. Number of eosin tanks: 1
7. Number of anti-blue cylinders: 1
8. Number of gradient alcohol tanks: 5
9. Number of end cylinders: 1
10. Single cylinder processing time: can be set arbitrarily from 1 second to 59 minutes
11. The temperature setting range of the hematoxylin tank and the warm water return tank is adjustable from 0 to 99 degrees.
12. Dyeing steps: 18 steps
13. Number of stained slides in a single staining rack: 20 slides
14. Infinite loop working mode of three dyeing racks
15. Single dyeing time: 4 minutes adjustable
16. The computer-programmed water inlet and sewage drainage system ensures that the water
quality is clean and water-saving when cleaning glass slides in each process.
17. Hematoxylin can be heated in a water bath, and can be colored quickly using ultrasonic waves.
The temperature can be set arbitrarily (patented)
18. The differentiation cylinder has precise priority processing
19. Eohong cylinder has precise priority processing
20. A single staining can reach 20 slides to meet the requirements of breast resection technology
21. Three methods of returning to blue are available, among which the warm water heating method
is sufficient and the temperature can be set arbitrarily (patented)
22. The dyeing rack has automatic identification function
23. It has an alarm function after the program is completed.
24. Numbers of programs: 10 programs
Net Weight: 55kg
Dimensions: 810*430*450mm

Package Info:
Each instrument packed Wooden Case
Gross Weight: 70kg
Dimensions:880*510*535mm